Learn More About Dielectric Withstand Or Hipot Tester Procedures From An Industrial Engineering Perspective

By Carl Hughes


Dielectric Strength or Hi Pot testings are completed by applying massive voltage against testing wire and ground, usually locomotive chassis. On the off chance that excess current spills or if a current arc happens, test show failure. Insulation Resistance tests give numbers showing resistance insulation. Data on how hipot testers function are found below.

High Pots could be AC, DC and conducted sporadically, or at final assembly line stage, etc. Stress assessment results, in general, illustrates Pass Fail basing on current leak. For several systems, this method may bear out risks. Testing medium volt wire might also pose dangers.

Dielectric strength illustrates max electric field pure substances could endure under optimal conditions without tearing or without showing breakdown of its insulating attributes. Theoretical dielectric withstand is a natural object attribute on raw material and autonomously designed material or electrodes to which electrical field is flowed. This innate dielectric withstand communicate data on what needs measuring using raw materials subjected upon optimal laboratory setting.

At breakdown, electrical fields free bounded electrons. If applied electrical fields are sufficiently high, freed electrons from surrounding radiation might accelerate with velocities which could liberate further electrons during neutral atom molecule collision in a course termed avalanche breakdown. Avalanche Breakdowns take place somewhat quickly, in nanoseconds normally, resulting into an electrically conducive path structure and disrupting electron release throughout an object. For concrete materials, avalanche breakdown event rigorously debase, even demolish said materials insulating potential.

Regarding difference between insulation and dielectric testing, none exists. There should be no difference between insulation versus dielectric testing. Dielectrical strength simply shows how well insulator material. Now regarding testing, frequency test voltage should be determined by what voltage type insulating substance will expect during its operational life. Which means you should not DC withstand testing component that will be used for AC 5060 Hz applications.

Whilst they are only two particular and altogether different techniques, these terms are irresponsibly tossed around reciprocally in trade. So you cannot without much stretch depend on those names precisely portraying what is being examined closely by way test was done. For instance, in Practice manual Dielectric Tests, wherein Di electric Tests within definition is mix of HiPot tests Insulation Resistance tests.

Though, commonly, HiPot analyzer being utilized for Di electric Quality test would satisfy usage towards Insulation Resistance analyzation. Particular terminology utilization would truly rely upon trade you are working, managing. In the event that it truly matters, you have to read given methodology label itself.

Insulation Resistance test will show DC most of the time. Di electric withstand test will commonly be AC yet can be DC. When one studies AC DC removal as one investigates similar subjects, previous experiments regarding above topic were conducted by research engineers. Final results show both are still required since they offer very distinct information.

A highlight unto interchangeability of these voltage tests is insignificant since all things considered, almost all manufactured insulated products undergo both tests since pigeon holing manufactured product into utilizing only one type of voltage frequency or electric transmission will always work for either provided they both have the same amount. Applying a 48v DC system with 650v AC secondary rated materials should be enough. Basically, not failing hipot would suffice regardless of insulating matter applied with.




About the Author: